30 kW Power Module

H2FC-30kW-mod-typ1.2
|
|
Operating Power |
6 – 30 kW continue |
Voltage |
160-300 VDC |
Volume |
0,5 m3 without H2 storage |
Dimensions (mm) |
1400 x 800 x 550 |
Efficiency |
52% @ nominal power |
Peak efficiency |
60% @ 50% power |
Ambient temperature [1] |
-30 °C to +40 °C |
Emission
|
water |
Operating temperature |
60-65 °C |
Life time |
12 year |
Module weight (excl. frame) |
200 kg |
Heavy duty frame weight |
220 kg |
Maintenance requirements
|
|
Air filter replacement |
2000 hrs |
Coolant conductivity test |
2000 hrs |
Coolant cleaner replacement |
6000 hrs |
H2 leakage test |
2000 hrs, at least 1x per year |
H2 sensor check/calibration |
every year |
High voltage leakage check |
every year |
Refurbishment interval FC stacks |
>25.000 hrs |
|
|
|
|
[1] during operation the module keeps itself warm. The system has an internal heater connected to the onboard 24 V batteries to keep the system above 5 °C when not operative.