30 kW Power Module
H2FC-30kW-mod-typ1.2
| |
|
| Operating Power |
6 – 30 kW continue |
| Voltage |
160-300 VDC |
| Volume |
0,5 m3 without H2 storage |
| Dimensions (mm) |
1400 x 800 x 550 |
| Efficency |
52% @ nominal power |
| Peak efficiency |
60% @ 50% power |
| Ambient temperature [1] |
-30 °C to +40 °C |
Emission
|
water |
| Operating temperature |
60-65 °C |
| Life time |
12 year |
| Module weight (excl. frame) |
200 kg |
| Heavy duty frame weight |
220 kg |
Maintenance requirements
|
|
| Air filter replacement |
2000 hrs |
| Coolant conductivity test |
2000 hrs |
| Coolant cleaner replacement |
6000 hrs |
| H2 leakage test |
2000 hrs, at least 1x per year |
| H2 sensor check/calibration |
every year |
| High voltage leakage check |
every year |
| Refurbishment interval FC stacks |
>25.000 hrs |
| |
|
| |
|
[1] during operation the module keeps itself warm. The system has an internal heater connected to the onboard 24 V batteries to keep the system above 5 °C when not operative.